[1] | ISO 6141 | Gas analysis - Requirements for certificates for calibration gases and gas mixtures (ИСО 6141 Анализ газов. Требования к сертификатам на газы и газовые смеси для калибрования) | |
[2] | ISO 6145 (all parts) | Gas analysis - Preparation of calibration gas mixtures using dynamic volumetric methods (ИСО 6145 Анализ газов. Приготовление газовых смесей для калибрования с использованием динамических объемных методов. Все части) | |
[3] | ISO 12219-1 | Indoor air - Road vehicles - Part 1: Whole vehicle test chamber - Specification and method for the determination of volatile organic compounds in car interiors (ГОСТ Р ИСО 12219-1 Воздух внутреннего пространства автотранспортных средств. Часть 1. Камера для испытания автотранспортного средства. Технические требования и условия испытания для определения летучих органических соединений в воздухе салона) | |
[4] | ISO 12219-2 | Indoor air of road vehicles - Part 2: Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials - Bag method (ГОСТ Р ИСО 12219-2 Воздух внутреннего пространства автотранспортных средств. Часть 2. Скрининг выделения летучих органических соединений материалами внутренней отделки и деталей салона. Метод с применением эластичных емкостей) | |
[5] | ISO 12219-3 | Indoor air of road vehicles - Part 3: Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials - Micro-chamber method (ГОСТ Р ИСО 12219-3 Воздух внутреннего пространства автотранспортных средств. Часть 3. Скрининг выделения летучих органических соединений материалами внутренней отделки и деталей салона. Метод с применением микрокамеры) | |
[6] | ISO 12219-4 | Indoor air of road vehicles - Part 4: Determination of the emissions of volatile organic compounds from car trim components - Small chamber method (ИСО 12219-4 Воздух внутреннего пространства автотранспортных средств. Часть 4. Метод определения выделений летучих органических соединений материалами внутренней отделки и деталей салона. Метод с применением небольшой камеры) | |
[7] | ISO 12219-5 | Indoor air of road vehicles - Part 5: Screening method for the determination of emissions of volatile organic compounds (VOC) from car trim components - Static chamber method (ИСО 12219-5 Воздух внутреннего пространства автотранспортных средств. Часть 5. Скрининговый метод для определения выделения летучих органических соединений материалами внутренней отделки и деталей салона. Метод с применением стационарной камеры) | |
_______________ В стадии подготовки. | |||
[8] | ISO 16017-2 | Indoor, ambient and workplace air - Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography - Part 2: Diffusive sampling (ГОСТ Р ИСО 16017-2 Воздух атмосферный, рабочей зоны и замкнутых помещений. Отбор проб летучих органических соединений при помощи сорбционной трубки с последующей термодесорбцией и газохроматографическим анализом на капиллярных колонках. Часть 2. Диффузионный метод отбора) | |
[9] | ISO/IEC Guide 98-3 | Uncertainty of measurement - Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) | |
[10] | ASTM D3686 | Standard Practice for Sampling Atmospheres to Collect Organic Compound Vapors (Activated Charcoal Tube Adsorption Method) | |
[11] | EN 1232 | Workplace atmospheres - Pumps for personal sampling of chemical agents - Requirements and test methods | |
[12] | MDHS 72 | Methods for the determination of hazardous substances - Volatile organic compounds in air - Laboratory method using pumped solid sorbent tubes, thermal desorption and gas chromatography. London: Health and Safety Executive, 1993. Available (viewed 2011-11-16) at: http://www.hse.qov.uk/pubns/mdhs/pdfs/mdhs72.pdf | |
[13] | Tirkkonen Т., Mroueh U-M., Orko I. Tenax as a collection medium for volatile organic compounds. Helsinki: NKB, 1995, 53 p. (NKB Committee and Work Reports 1995:06 E.) | ||
[14] | World Health Organization. Indoor air quality: Organic pollutants. Copenhagen: WHO Regional Office for Europe, 1989. 70 p. (EURO Reports and Studies No.111.) Available (viewed 2011-11-16) at: | ||
[15] | Lewis R.G., Gordon S.M. Sampling of organic chemicals in air. In: KEITH, L.H., editor. Principles of environmental sampling, 2nd edition, pp.401-470. Washington DC: American Chemical Society, 1996 | ||
[16] | Hafkenscheid Т., Wilkinson G. Assessment of the uncertainty of measurement results of hexachlorobutadiene in indoor air. In: Indoor Air 2002 - 9th International Conference on Indoor Air Quality and Climate, 2002-06-30/07-05, Monterey, CA, pp.926-931. Available (viewed 2011-11-16) at: | ||
[17] | De Bortoli M., H., Pecchio E., Schauenburg H., Vissers H. Comparison of Tenaxand Carbotrap for VOC sampling in indoor air. Indoor Air 1992, 2, pp.216-224 | ||
[18] | ECA Report No 13, Determination of VOCs emitted from indoor materials and products. Interlaboratory comparison of small chamber measurements. Luxemburg: Commission of the European Communities, 1993, 90 p. Available (viewed 2011-11-16) at: http://www.inive.org/medias/ECA/ECA Report13.pdf | ||
[19] | ECA Report No 16, Determination of VOCs emitted from indoor materials and products: Second interlaboratory comparison of small chamber measurements. Luxemburg: Commission of the European Communities, 1995, 76 p. Available (viewed 2011-11-16) at: http://www.inive.org/medias/ECA/ECA Report16.pdf | ||
[20] | ECA Report No 18, Evaluation of VOC emissions from building materials: Solid flooring materials. Luxemburg: Commission of the European Communities, 1997, 108 p. Available (viewed 2011-11-16) at: http://www.inive.org/medias/ECA/ECA Report18.pdf | ||
[21] | ECA Report No 19, Total volatile organic compounds (TVOC) in indoor air quality investigations. Luxemburg: Commission of the European Communities, 1997. 56 p. Available (viewed 2011-11-16) at: http://www.inive.org/medias/ECA/ECA Report19.pdf | ||
[22] | Verschueren K. Handbook of environmental data on organic chemicals, 5th edition, 4 vols. Hoboken, NJ: Wiley, 2009. 4358 p. | ||
[23] | Johnson P.C., Kemblowski M.W., Colthart J.D. Practical screening models for soil venting applications. In: Proc. NWWA/API, Conference on petroleum hydrocarbons and organic chemicals in groundwater, Houston, TX, 1988-11-09/11, Vol.2, pp.521-546. Westerville, OH: National Ground Water Association, 1989. Available (viewed 2011-11-16) at: http://info.ngwa.org/GWOL/pdf/890152158.pdf | ||
[24] | International labour organization. International Chemical Safety Cards. Available (viewed 2011-11-16) at: |
УДК 504.3:006.354 | МКС 13.040.20 | Т58 |
Ключевые слова: воздух, замкнутое помещение, летучие органические соединения, отбор проб, сорбент, сорбционная трубка, термическая десорбция, газохроматический |
Редакция документа с учетом
изменений и дополнений подготовлена
АО "Кодекс"